De 1600Hz krachtpatser

MSR 165 Shock logger

Terug naar vorige pagina

Measured Parameters

3-Axis Acceleration (Built-in Internal)

Temperature (Internal or External)

Relative Humidity (Internal or External)

Air Pressure (Internal or External)

Light (Internal)

Analog Input Signal (External)

Acceleration

Range: ±200G

Accuracy: ±0.15G @25°C

Temperature

Range: -20°C to 65°C (Internal); -55°C to 125°C (External)

Accuracy: ±0.3°C (Internal);±2.0°C (External)

Humidity

Range: 0 to 100% RH, -20°C to 65°C

Accuracy: ±2% (10 to 85% RH, 0°C to 40°C); ±4% (85 to 95% RH, 0°C to 40°C); ±0.5°C (0°C to 65°C)

Pressure

Range: 0 to 2000 mbar Absolute or 0 to 14 Bar Absolute

Accuracy: ±2.5mbar (750 to 1100 mbar Absolute, 25C); ±0.5°C (0°C to 65°C)

Light

Type: SFH 5712 Osram

Range: 0 to 65,000 lx

Accuracy: 100 to 65,000 lx, Max ±5% Linearity Error, Max Sensitivity at 500 nm

Resolution: 4 lx

Temperature Coefficient: 0°C to 50°C, <0.2%/K

Analog Input

Range: 0 to 3.0 Volts

Resolution: 12 Bits

Sampling Rate

Acceleration: Up to 1600/s

Temperature: 1/s to 12 Hours

Humidity: 1/s to 12 Hours

Pressure: 1/s to 12 Hours

Light Level: 1/s to 12 Hours

Data Storage Capacity

Approximately 2,000,000 Total Readings

Additional Storage Available with Standard SD (>4 GB) Card

Operating Conditions

Temperature: -20°C to 65°C

Storage Conditions

Temperature: 5°C to 45°C

Humidity: 10 to 95% RH, non-condensing

Color

Blue, Anthracite

Recording Mode

Set Bookmark or Start and Stop Recording

Power Supply

Rechargeable Lithium Polymer Battery (900mAh)

>> USB Connection to PC recharges unit

>> At a Measurement Rate of 1600/s up to once every 12 Hours, 3-Axis Acceleration data can be recorded over a period of 6 months

Housing Enclosure

Anodised Aluminum Case, PC, Not Encapsulated , Waterproof

Media

Air, Various Liquids

Standards Compliance

RoHS/WEEE, IP67

Software Compatible

Windows 7, Vista, XP, 2000, NT, ME, 98, 95

Dimensions

39mm x 23mm x 72mm

Weight

64 grams

Terug naar vorige pagina